A. Anterior and posterior restorations
A-1. Cleaning of tooth surface Thoroughly clean the tooth surface to remove plaque
A-2. Shade selection Select appropriate shade using a shade guide while the tooth is still moist
A-3. Cavity preparation Prepare the cavity following the conventional method
A-4. Isolation Isolate with a rubber dam
A-5. Pulp protection In the case where the affected area is close to the pulp, cap the pulp with calcium hydroxide etc.
• Do not use eugenol containing materials since they
might inhibit polymerization or adhesion of the material
A-6. Conditioning and application of adhesive Apply dentin adhesive following the manufacturer’s instructions for use
A-7. Setting of a Needle Tip Follow the instructions below to attach the BEAUTIFIL Needle Tip provided.
1. Pull off the shield cap while turning it slowly
2. Attach the needle tip by turning it clockwise until it is securely attached
• Wear clean medical (dental gloves) when replacing the needle tip
A-8. Placement Apply necessary amount of BEAUTIFIL Flow directly into the cavity and create the shape desired. BEAUTIFIL Flow may also be extruded onto a paper pad to be applied into the cavity with a suitable instru- ment
• When storing these materials in a refrigerator, allow them to reach room temperature before use
• The paste dispensed onto the paper pad should be shielded from ambient light by light-shielding cover to avoid unintended polymerization of the material. • Needle tips should be used for only one patient and then discarded at the end of the procedure to avoid cross contamination
A-9. Light-curing Light-cure using a dental light-curing unit.
• When the cavity is deep, incremental filling and lightcuring not exceeding 2 mm is recommended.
• When the cavity surface is large, light-cure in seg- ments
• Dental light-curing unit and light-curing time
A-10. Finishing and polishing After light-curing, contour, finish and polish the restora- tion following the conventional method
B. Base / Liner
B-1. Follow ″A-1″-″A-7″ procedures of Anterior and posterior restorations above
B-2. Base / Liner Apply necessary amount of BEAUTIFIL Flow directly into the cavity and create the shape desired. BEAU- TIFIL Flow may also be extruded onto a paper pad to be applied into the cavity with a suitable instrument. Light-cure the material using a dental light-curing unit (Halogen : 30 sec. or LED : 10 sec.)
• When storing these materials in a refrigerator, allow them to reach room temperature before use
• The paste dispensed onto the paper pad should be shielded from ambient light by light-shielding cover to avoid unintended polymerization of the material
• Needle tips should be used for only one patient and then discarded at the end of the procedure to avoid cross contamination
B-3. Placement Fill direct composite resin
B-4. Finishing and polishing After light-curing, contour, finish and polish the restora- tion following the conventional method.
Reviews
There are no reviews yet.