Anand HI-Vac (JR) Suction Units

US$559.00US$640.00 (-13%)

In stock

Anand HI-Vac (JR) Suction Units

  • MS / SS Housing: Available in Mild Steel (MS) and Stainless Steel (SS).
  • Electronic Sensor: To prevent splash droplets from entering the pump.
  • Vacuum Gauge: 2.5 inches round vacuum gauge.
  • Pump: A single head rotary vane pump.

Description

A smaller version of our Hi-Vac suction series for use in surgical procedures where fast vacuum build-up is required.

MAIN APPLICATIONS

  • Emergency Department
  • Intensive Care Unit
  • OT / Surgery
  • Endoscopy
  • Obstetrics / Gynaecology
  • Gastroenterology

Key Specifications

TECHNICAL SPECIFICATIONS :

Housing MS / Stainless Steel on four castors
Max. Vacuum / LPM -650 mm Hg, 42 Ltrs / min
Pump Type Single Rotary vane pump
Jars 2 x 2 Ltrs. PC Jar
Filter Trap Filter with inbuilt overflow protection
Tubing 10 mm ID x 2 mtr. (PVC)
Vacuum Gauge 6.25 cm dia 0-760 mm Hg
Power Supply 220 V AC, 50 / 60 Hz, 130 Watt
Noise Level 50 dB A ± 3
Dimensions 39 x 31 x 62 cms
Net Weight 25 Kg
Overflow Safety Dual Mechanical

 

Packaging

  • 1 x Suction Unit
  • 2 x 2 Ltr. Jars

Direction to Use

GUIDELINES FOR USE:

1. LUBRICATION : The unit must be lubricated with good quality oil (Mobil oil no.40) as soon as container gets empty. This way not only you get good suction but good service for years together.

2. NEGATIVE PRESSURE : Before the unit is put to use, vacuum must be set at the required level. Fully tightened (clockwise) vacuum control knob means full vacuum. Even otherwise, replacing of gauze/refill is suggested every six months.

3. JARS : As the flow rate is high, 3/4th filling of jar is recommended; otherwise splash droplets might enter the filter and if not cleaned regularly might enter the pump.

4. CLEANING : After each use, lids overflow cut-off valve, suction cannulae, catheters etc. should be cleaned thoroughly. When sterilization is necessary after infective fluid has been sucked, the jars, the lids, cut-off valve and metal cannulae can be sterilized by autoclaving and the tubing, by sterilizing solution.

6. PUMP: But if accidentally the fluid enters the pump, pullout the filter and run the unit by keeping a thumb on the suction inlet for a minute or two. Unscrew and take out the pin from the vacuum control knob and with the pump still on, gradually pour, 15-20 drops of mobil oil in it. Block the inlet “OFF” and “ON” for a couple of times. Put the knob pin and the filter in their respective places.

If it does not start, please consult the hospital engineer or the electrician. If this exercise is not done immediately after the accidental entry of blood in the pump, the blood will stick dry inside the pump, housing and the whole pump will have to be opened , cleaned, lubricated and set again. For this open the side door, remove plastic tubing (inlet point) and exhaust silencer (outlet points with metal point ‘L’ tubes). To dilute the dried blood, pour few drops of kerosene oil/diesel and make the unit on-off. After it takes a start keep the unit running and gradually pour 10-20 of mobil oil in the running unit. After say a run of 30 minutes or more put the tubing exhaust outlets and door back to its original position. The outlet point (exhaust) inside the housing can be opened cleaned and gauze/refill replaced in it. Even otherwise, replacing of gauze/refill is suggested every six months.

Warranty

  • Manufacturer/Importer warranty of 1 Year against manufacturing defect
  • Service and Warranty are handled by the manufacturer/importer directly for this product
  • Dentalkart will not be liable to replace the Products and the liability to replace any such Product is that of the Manufacturer/Importer
  • Dentalkart and the Buyer acknowledge that the Products purchased/usedare a subject matter of original Manufacturer/Importer’s warranties only
  • Any or all claims in relation to returns and replacement shall be made to the concerned Manufacturer/Importer only and Dentalkart may assist the customer in registering a request to get the Product replaced or serviced. 
  • The Buyer acknowledges that the Products once sold will not be exchanged or taken back unless the seal of the package or the Product is intact or not altered in any manner or is not tampered as the case may be.

Only logged in customers who have purchased this product may leave a review.

Reviews

There are no reviews yet.

Main Menu

Anand HI-Vac (JR) Suction Units

US$559.00US$640.00 (-13%)

Add to cart